1
mirror of https://github.com/home-assistant/core synced 2024-08-28 03:36:46 +02:00
ha-core/homeassistant/components/sunweg/__init__.py
2023-12-18 10:03:40 -10:00

197 lines
7.2 KiB
Python

"""The Sun WEG inverter sensor integration."""
import datetime
import json
import logging
from sunweg.api import APIHelper
from sunweg.plant import Plant
from homeassistant import config_entries
from homeassistant.config_entries import ConfigEntry
from homeassistant.const import CONF_PASSWORD, CONF_USERNAME
from homeassistant.core import HomeAssistant
from homeassistant.helpers.typing import StateType, UndefinedType
from homeassistant.util import Throttle
from .const import CONF_PLANT_ID, DOMAIN, PLATFORMS, DeviceType
SCAN_INTERVAL = datetime.timedelta(minutes=5)
_LOGGER = logging.getLogger(__name__)
async def async_setup_entry(
hass: HomeAssistant, entry: config_entries.ConfigEntry
) -> bool:
"""Load the saved entities."""
api = APIHelper(entry.data[CONF_USERNAME], entry.data[CONF_PASSWORD])
if not await hass.async_add_executor_job(api.authenticate):
_LOGGER.error("Username or Password may be incorrect!")
return False
hass.data.setdefault(DOMAIN, {})[entry.entry_id] = SunWEGData(
api, entry.data[CONF_PLANT_ID]
)
await hass.config_entries.async_forward_entry_setups(entry, PLATFORMS)
return True
async def async_unload_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
"""Unload a config entry."""
hass.data[DOMAIN].pop(entry.entry_id)
if len(hass.data[DOMAIN]) == 0:
hass.data.pop(DOMAIN)
return await hass.config_entries.async_unload_platforms(entry, PLATFORMS)
class SunWEGData:
"""The class for handling data retrieval."""
def __init__(
self,
api: APIHelper,
plant_id: int,
) -> None:
"""Initialize the probe."""
self.api = api
self.plant_id = plant_id
self.data: Plant = None
self.previous_values: dict = {}
@Throttle(SCAN_INTERVAL)
def update(self) -> None:
"""Update probe data."""
_LOGGER.debug("Updating data for plant %s", self.plant_id)
try:
self.data = self.api.plant(self.plant_id)
for inverter in self.data.inverters:
self.api.complete_inverter(inverter)
except json.decoder.JSONDecodeError:
_LOGGER.error("Unable to fetch data from SunWEG server")
_LOGGER.debug("Finished updating data for plant %s", self.plant_id)
def get_api_value(
self,
variable: str,
device_type: DeviceType,
inverter_id: int = 0,
deep_name: str | None = None,
):
"""Retrieve from a Plant the desired variable value."""
if device_type == DeviceType.TOTAL:
return self.data.__dict__.get(variable)
inverter_list = [i for i in self.data.inverters if i.id == inverter_id]
if len(inverter_list) == 0:
return None
inverter = inverter_list[0]
if device_type == DeviceType.INVERTER:
return inverter.__dict__.get(variable)
if device_type == DeviceType.PHASE:
for phase in inverter.phases:
if phase.name == deep_name:
return phase.__dict__.get(variable)
elif device_type == DeviceType.STRING:
for mppt in inverter.mppts:
for string in mppt.strings:
if string.name == deep_name:
return string.__dict__.get(variable)
return None
def get_data(
self,
*,
api_variable_key: str,
api_variable_unit: str | None,
deep_name: str | None,
device_type: DeviceType,
inverter_id: int,
name: str | UndefinedType | None,
native_unit_of_measurement: str | None,
never_resets: bool,
previous_value_drop_threshold: float | None,
) -> tuple[StateType | datetime.datetime, str | None]:
"""Get the data."""
_LOGGER.debug(
"Data request for: %s",
name,
)
variable = api_variable_key
previous_unit = native_unit_of_measurement
api_value = self.get_api_value(variable, device_type, inverter_id, deep_name)
previous_value = self.previous_values.get(variable)
return_value = api_value
if api_variable_unit is not None:
native_unit_of_measurement = self.get_api_value(
api_variable_unit,
device_type,
inverter_id,
deep_name,
)
# If we have a 'drop threshold' specified, then check it and correct if needed
if (
previous_value_drop_threshold is not None
and previous_value is not None
and api_value is not None
and previous_unit == native_unit_of_measurement
):
_LOGGER.debug(
(
"%s - Drop threshold specified (%s), checking for drop... API"
" Value: %s, Previous Value: %s"
),
name,
previous_value_drop_threshold,
api_value,
previous_value,
)
diff = float(api_value) - float(previous_value)
# Check if the value has dropped (negative value i.e. < 0) and it has only
# dropped by a small amount, if so, use the previous value.
# Note - The energy dashboard takes care of drops within 10%
# of the current value, however if the value is low e.g. 0.2
# and drops by 0.1 it classes as a reset.
if -(previous_value_drop_threshold) <= diff < 0:
_LOGGER.debug(
(
"Diff is negative, but only by a small amount therefore not a"
" nightly reset, using previous value (%s) instead of api value"
" (%s)"
),
previous_value,
api_value,
)
return_value = previous_value
else:
_LOGGER.debug("%s - No drop detected, using API value", name)
# Lifetime total values should always be increasing, they will never reset,
# however the API sometimes returns 0 values when the clock turns to 00:00
# local time in that scenario we should just return the previous value
# Scenarios:
# 1 - System has a genuine 0 value when it it first commissioned:
# - will return 0 until a non-zero value is registered
# 2 - System has been running fine but temporarily resets to 0 briefly
# at midnight:
# - will return the previous value
# 3 - HA is restarted during the midnight 'outage' - Not handled:
# - Previous value will not exist meaning 0 will be returned
# - This is an edge case that would be better handled by looking
# up the previous value of the entity from the recorder
if never_resets and api_value == 0 and previous_value:
_LOGGER.debug(
(
"API value is 0, but this value should never reset, returning"
" previous value (%s) instead"
),
previous_value,
)
return_value = previous_value
self.previous_values[variable] = return_value
return (return_value, native_unit_of_measurement)