"""Provides a sensor to track various status aspects of a UPS."""
from datetime import timedelta
import logging
from pynut2.nut2 import PyNUTClient, PyNUTError
import voluptuous as vol
from homeassistant.components.sensor import PLATFORM_SCHEMA
from homeassistant.const import (
ATTR_STATE,
CONF_ALIAS,
CONF_HOST,
CONF_NAME,
CONF_PASSWORD,
CONF_PORT,
CONF_RESOURCES,
CONF_USERNAME,
POWER_WATT,
STATE_UNKNOWN,
TEMP_CELSIUS,
TIME_SECONDS,
UNIT_PERCENTAGE,
)
from homeassistant.exceptions import PlatformNotReady
import homeassistant.helpers.config_validation as cv
from homeassistant.helpers.entity import Entity
from homeassistant.util import Throttle
_LOGGER = logging.getLogger(__name__)
DEFAULT_NAME = "NUT UPS"
DEFAULT_HOST = "localhost"
DEFAULT_PORT = 3493
KEY_STATUS = "ups.status"
KEY_STATUS_DISPLAY = "ups.status.display"
MIN_TIME_BETWEEN_UPDATES = timedelta(seconds=60)
SENSOR_TYPES = {
"ups.status.display": ["Status", "", "mdi:information-outline"],
"ups.status": ["Status Data", "", "mdi:information-outline"],
"ups.alarm": ["Alarms", "", "mdi:alarm"],
"ups.time": ["Internal Time", "", "mdi:calendar-clock"],
"ups.date": ["Internal Date", "", "mdi:calendar"],
"ups.model": ["Model", "", "mdi:information-outline"],
"ups.mfr": ["Manufacturer", "", "mdi:information-outline"],
"ups.mfr.date": ["Manufacture Date", "", "mdi:calendar"],
"ups.serial": ["Serial Number", "", "mdi:information-outline"],
"ups.vendorid": ["Vendor ID", "", "mdi:information-outline"],
"ups.productid": ["Product ID", "", "mdi:information-outline"],
"ups.firmware": ["Firmware Version", "", "mdi:information-outline"],
"ups.firmware.aux": ["Firmware Version 2", "", "mdi:information-outline"],
"ups.temperature": ["UPS Temperature", TEMP_CELSIUS, "mdi:thermometer"],
"ups.load": ["Load", UNIT_PERCENTAGE, "mdi:gauge"],
"ups.load.high": ["Overload Setting", UNIT_PERCENTAGE, "mdi:gauge"],
"ups.id": ["System identifier", "", "mdi:information-outline"],
"ups.delay.start": ["Load Restart Delay", TIME_SECONDS, "mdi:timer"],
"ups.delay.reboot": ["UPS Reboot Delay", TIME_SECONDS, "mdi:timer"],
"ups.delay.shutdown": ["UPS Shutdown Delay", TIME_SECONDS, "mdi:timer"],
"ups.timer.start": ["Load Start Timer", TIME_SECONDS, "mdi:timer"],
"ups.timer.reboot": ["Load Reboot Timer", TIME_SECONDS, "mdi:timer"],
"ups.timer.shutdown": ["Load Shutdown Timer", TIME_SECONDS, "mdi:timer"],
"ups.test.interval": ["Self-Test Interval", TIME_SECONDS, "mdi:timer"],
"ups.test.result": ["Self-Test Result", "", "mdi:information-outline"],
"ups.test.date": ["Self-Test Date", "", "mdi:calendar"],
"ups.display.language": ["Language", "", "mdi:information-outline"],
"ups.contacts": ["External Contacts", "", "mdi:information-outline"],
"ups.efficiency": ["Efficiency", UNIT_PERCENTAGE, "mdi:gauge"],
"ups.power": ["Current Apparent Power", "VA", "mdi:flash"],
"ups.power.nominal": ["Nominal Power", "VA", "mdi:flash"],
"ups.realpower": ["Current Real Power", POWER_WATT, "mdi:flash"],
"ups.realpower.nominal": ["Nominal Real Power", POWER_WATT, "mdi:flash"],
"ups.beeper.status": ["Beeper Status", "", "mdi:information-outline"],
"ups.type": ["UPS Type", "", "mdi:information-outline"],
"ups.watchdog.status": ["Watchdog Status", "", "mdi:information-outline"],
"ups.start.auto": ["Start on AC", "", "mdi:information-outline"],
"ups.start.battery": ["Start on Battery", "", "mdi:information-outline"],
"ups.start.reboot": ["Reboot on Battery", "", "mdi:information-outline"],
"ups.shutdown": ["Shutdown Ability", "", "mdi:information-outline"],
"battery.charge": ["Battery Charge", UNIT_PERCENTAGE, "mdi:gauge"],
"battery.charge.low": ["Low Battery Setpoint", UNIT_PERCENTAGE, "mdi:gauge"],
"battery.charge.restart": [
"Minimum Battery to Start",
UNIT_PERCENTAGE,
"mdi:gauge",
],
"battery.charge.warning": [
"Warning Battery Setpoint",
UNIT_PERCENTAGE,
"mdi:gauge",
],
"battery.charger.status": ["Charging Status", "", "mdi:information-outline"],
"battery.voltage": ["Battery Voltage", "V", "mdi:flash"],
"battery.voltage.nominal": ["Nominal Battery Voltage", "V", "mdi:flash"],
"battery.voltage.low": ["Low Battery Voltage", "V", "mdi:flash"],
"battery.voltage.high": ["High Battery Voltage", "V", "mdi:flash"],
"battery.capacity": ["Battery Capacity", "Ah", "mdi:flash"],
"battery.current": ["Battery Current", "A", "mdi:flash"],
"battery.current.total": ["Total Battery Current", "A", "mdi:flash"],
"battery.temperature": ["Battery Temperature", TEMP_CELSIUS, "mdi:thermometer"],
"battery.runtime": ["Battery Runtime", TIME_SECONDS, "mdi:timer"],
"battery.runtime.low": ["Low Battery Runtime", TIME_SECONDS, "mdi:timer"],
"battery.runtime.restart": [
"Minimum Battery Runtime to Start",
TIME_SECONDS,
"mdi:timer",
],
"battery.alarm.threshold": [
"Battery Alarm Threshold",
"",
"mdi:information-outline",
],
"battery.date": ["Battery Date", "", "mdi:calendar"],
"battery.mfr.date": ["Battery Manuf. Date", "", "mdi:calendar"],
"battery.packs": ["Number of Batteries", "", "mdi:information-outline"],
"battery.packs.bad": ["Number of Bad Batteries", "", "mdi:information-outline"],
"battery.type": ["Battery Chemistry", "", "mdi:information-outline"],
"input.sensitivity": ["Input Power Sensitivity", "", "mdi:information-outline"],
"input.transfer.low": ["Low Voltage Transfer", "V", "mdi:flash"],
"input.transfer.high": ["High Voltage Transfer", "V", "mdi:flash"],
"input.transfer.reason": ["Voltage Transfer Reason", "", "mdi:information-outline"],
"input.voltage": ["Input Voltage", "V", "mdi:flash"],
"input.voltage.nominal": ["Nominal Input Voltage", "V", "mdi:flash"],
"input.frequency": ["Input Line Frequency", "hz", "mdi:flash"],
"input.frequency.nominal": ["Nominal Input Line Frequency", "hz", "mdi:flash"],
"input.frequency.status": ["Input Frequency Status", "", "mdi:information-outline"],
"output.current": ["Output Current", "A", "mdi:flash"],
"output.current.nominal": ["Nominal Output Current", "A", "mdi:flash"],
"output.voltage": ["Output Voltage", "V", "mdi:flash"],
"output.voltage.nominal": ["Nominal Output Voltage", "V", "mdi:flash"],
"output.frequency": ["Output Frequency", "hz", "mdi:flash"],
"output.frequency.nominal": ["Nominal Output Frequency", "hz", "mdi:flash"],
}
STATE_TYPES = {
"OL": "Online",
"OB": "On Battery",
"LB": "Low Battery",
"HB": "High Battery",
"RB": "Battery Needs Replaced",
"CHRG": "Battery Charging",
"DISCHRG": "Battery Discharging",
"BYPASS": "Bypass Active",
"CAL": "Runtime Calibration",
"OFF": "Offline",
"OVER": "Overloaded",
"TRIM": "Trimming Voltage",
"BOOST": "Boosting Voltage",
"FSD": "Forced Shutdown",
"ALARM": "Alarm",
}
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Optional(CONF_HOST, default=DEFAULT_HOST): cv.string,
vol.Optional(CONF_PORT, default=DEFAULT_PORT): cv.port,
vol.Optional(CONF_ALIAS): cv.string,
vol.Optional(CONF_USERNAME): cv.string,
vol.Optional(CONF_PASSWORD): cv.string,
vol.Required(CONF_RESOURCES): vol.All(cv.ensure_list, [vol.In(SENSOR_TYPES)]),
}
)
def setup_platform(hass, config, add_entities, discovery_info=None):
"""Set up the NUT sensors."""
name = config.get(CONF_NAME)
host = config.get(CONF_HOST)
port = config.get(CONF_PORT)
alias = config.get(CONF_ALIAS)
username = config.get(CONF_USERNAME)
password = config.get(CONF_PASSWORD)
data = PyNUTData(host, port, alias, username, password)
if data.status is None:
_LOGGER.error("NUT Sensor has no data, unable to set up")
raise PlatformNotReady
_LOGGER.debug("NUT Sensors Available: %s", data.status)
entities = []
for resource in config[CONF_RESOURCES]:
sensor_type = resource.lower()
# Display status is a special case that falls back to the status value
# of the UPS instead.
if sensor_type in data.status or (
sensor_type == KEY_STATUS_DISPLAY and KEY_STATUS in data.status
):
entities.append(NUTSensor(name, data, sensor_type))
else:
_LOGGER.warning(
"Sensor type: %s does not appear in the NUT status "
"output, cannot add",
sensor_type,
)
try:
data.update(no_throttle=True)
except data.pynuterror as err:
_LOGGER.error(
"Failure while testing NUT status retrieval. Cannot continue setup: %s", err
)
raise PlatformNotReady
add_entities(entities, True)
class NUTSensor(Entity):
"""Representation of a sensor entity for NUT status values."""
def __init__(self, name, data, sensor_type):
"""Initialize the sensor."""
self._data = data
self.type = sensor_type
self._name = "{} {}".format(name, SENSOR_TYPES[sensor_type][0])
self._unit = SENSOR_TYPES[sensor_type][1]
self._state = None
@property
def name(self):
"""Return the name of the UPS sensor."""
return self._name
@property
def icon(self):
"""Icon to use in the frontend, if any."""
return SENSOR_TYPES[self.type][2]
@property
def state(self):
"""Return entity state from ups."""
return self._state
@property
def unit_of_measurement(self):
"""Return the unit of measurement of this entity, if any."""
return self._unit
@property
def device_state_attributes(self):
"""Return the sensor attributes."""
attr = dict()
attr[ATTR_STATE] = self.display_state()
return attr
def display_state(self):
"""Return UPS display state."""
if self._data.status is None:
return STATE_TYPES["OFF"]
try:
return " ".join(
STATE_TYPES[state] for state in self._data.status[KEY_STATUS].split()
)
except KeyError:
return STATE_UNKNOWN
def update(self):
"""Get the latest status and use it to update our sensor state."""
if self._data.status is None:
self._state = None
return
# In case of the display status sensor, keep a human-readable form
# as the sensor state.
if self.type == KEY_STATUS_DISPLAY:
self._state = self.display_state()
elif self.type not in self._data.status:
self._state = None
else:
self._state = self._data.status[self.type]
class PyNUTData:
"""Stores the data retrieved from NUT.
For each entity to use, acts as the single point responsible for fetching
updates from the server.
"""
def __init__(self, host, port, alias, username, password):
"""Initialize the data object."""
self._host = host
self._port = port
self._alias = alias
self._username = username
self._password = password
self.pynuterror = PyNUTError
# Establish client with persistent=False to open/close connection on
# each update call. This is more reliable with async.
self._client = PyNUTClient(
self._host, self._port, self._username, self._password, 5, False
)
self._status = None
@property
def status(self):
"""Get latest update if throttle allows. Return status."""
self.update()
return self._status
def _get_alias(self):
"""Get the ups alias from NUT."""
try:
return next(iter(self._client.list_ups()))
except self.pynuterror as err:
_LOGGER.error("Failure getting NUT ups alias, %s", err)
return None
def _get_status(self):
"""Get the ups status from NUT."""
if self._alias is None:
self._alias = self._get_alias()
try:
return self._client.list_vars(self._alias)
except (self.pynuterror, ConnectionResetError) as err:
_LOGGER.debug("Error getting NUT vars for host %s: %s", self._host, err)
return None
@Throttle(MIN_TIME_BETWEEN_UPDATES)
def update(self, **kwargs):
"""Fetch the latest status from NUT."""
self._status = self._get_status()