"""Support for BH1750 light sensor."""
from functools import partial
import logging
from i2csense.bh1750 import BH1750 # pylint: disable=import-error
import smbus # pylint: disable=import-error
import voluptuous as vol
from homeassistant.components.sensor import PLATFORM_SCHEMA
from homeassistant.const import CONF_NAME, DEVICE_CLASS_ILLUMINANCE
import homeassistant.helpers.config_validation as cv
from homeassistant.helpers.entity import Entity
_LOGGER = logging.getLogger(__name__)
CONF_I2C_ADDRESS = "i2c_address"
CONF_I2C_BUS = "i2c_bus"
CONF_OPERATION_MODE = "operation_mode"
CONF_SENSITIVITY = "sensitivity"
CONF_DELAY = "measurement_delay_ms"
CONF_MULTIPLIER = "multiplier"
# Operation modes for BH1750 sensor (from the datasheet). Time typically 120ms
# In one time measurements, device is set to Power Down after each sample.
CONTINUOUS_LOW_RES_MODE = "continuous_low_res_mode"
CONTINUOUS_HIGH_RES_MODE_1 = "continuous_high_res_mode_1"
CONTINUOUS_HIGH_RES_MODE_2 = "continuous_high_res_mode_2"
ONE_TIME_LOW_RES_MODE = "one_time_low_res_mode"
ONE_TIME_HIGH_RES_MODE_1 = "one_time_high_res_mode_1"
ONE_TIME_HIGH_RES_MODE_2 = "one_time_high_res_mode_2"
OPERATION_MODES = {
CONTINUOUS_LOW_RES_MODE: (0x13, True), # 4lx resolution
CONTINUOUS_HIGH_RES_MODE_1: (0x10, True), # 1lx resolution.
CONTINUOUS_HIGH_RES_MODE_2: (0x11, True), # 0.5lx resolution.
ONE_TIME_LOW_RES_MODE: (0x23, False), # 4lx resolution.
ONE_TIME_HIGH_RES_MODE_1: (0x20, False), # 1lx resolution.
ONE_TIME_HIGH_RES_MODE_2: (0x21, False), # 0.5lx resolution.
}
SENSOR_UNIT = "lx"
DEFAULT_NAME = "BH1750 Light Sensor"
DEFAULT_I2C_ADDRESS = "0x23"
DEFAULT_I2C_BUS = 1
DEFAULT_MODE = CONTINUOUS_HIGH_RES_MODE_1
DEFAULT_DELAY_MS = 120
DEFAULT_SENSITIVITY = 69 # from 31 to 254
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Optional(CONF_I2C_ADDRESS, default=DEFAULT_I2C_ADDRESS): cv.string,
vol.Optional(CONF_I2C_BUS, default=DEFAULT_I2C_BUS): vol.Coerce(int),
vol.Optional(CONF_OPERATION_MODE, default=DEFAULT_MODE): vol.In(
OPERATION_MODES
),
vol.Optional(CONF_SENSITIVITY, default=DEFAULT_SENSITIVITY): cv.positive_int,
vol.Optional(CONF_DELAY, default=DEFAULT_DELAY_MS): cv.positive_int,
vol.Optional(CONF_MULTIPLIER, default=1.0): vol.Range(min=0.1, max=10),
}
)
async def async_setup_platform(hass, config, async_add_entities, discovery_info=None):
"""Set up the BH1750 sensor."""
name = config.get(CONF_NAME)
bus_number = config.get(CONF_I2C_BUS)
i2c_address = config.get(CONF_I2C_ADDRESS)
operation_mode = config.get(CONF_OPERATION_MODE)
bus = smbus.SMBus(bus_number)
sensor = await hass.async_add_job(
partial(
BH1750,
bus,
i2c_address,
operation_mode=operation_mode,
measurement_delay=config.get(CONF_DELAY),
sensitivity=config.get(CONF_SENSITIVITY),
logger=_LOGGER,
)
)
if not sensor.sample_ok:
_LOGGER.error("BH1750 sensor not detected at %s", i2c_address)
return False
dev = [BH1750Sensor(sensor, name, SENSOR_UNIT, config.get(CONF_MULTIPLIER))]
_LOGGER.info(
"Setup of BH1750 light sensor at %s in mode %s is complete",
i2c_address,
operation_mode,
)
async_add_entities(dev, True)
class BH1750Sensor(Entity):
"""Implementation of the BH1750 sensor."""
def __init__(self, bh1750_sensor, name, unit, multiplier=1.0):
"""Initialize the sensor."""
self._name = name
self._unit_of_measurement = unit
self._multiplier = multiplier
self.bh1750_sensor = bh1750_sensor
if self.bh1750_sensor.light_level >= 0:
self._state = int(round(self.bh1750_sensor.light_level))
else:
self._state = None
@property
def name(self) -> str:
"""Return the name of the sensor."""
return self._name
@property
def state(self) -> int:
"""Return the state of the sensor."""
return self._state
@property
def unit_of_measurement(self) -> str:
"""Return the unit of measurement of the sensor."""
return self._unit_of_measurement
@property
def device_class(self) -> str:
"""Return the class of this device, from component DEVICE_CLASSES."""
return DEVICE_CLASS_ILLUMINANCE
async def async_update(self):
"""Get the latest data from the BH1750 and update the states."""
await self.hass.async_add_job(self.bh1750_sensor.update)
if self.bh1750_sensor.sample_ok and self.bh1750_sensor.light_level >= 0:
self._state = int(round(self.bh1750_sensor.light_level * self._multiplier))
else:
_LOGGER.warning(
"Bad Update of sensor.%s: %s", self.name, self.bh1750_sensor.light_level
)