"""Support for Honeywell Lyric climate platform."""
from __future__ import annotations
import asyncio
import logging
from time import localtime, strftime, time
from aiolyric.objects.device import LyricDevice
from aiolyric.objects.location import LyricLocation
import voluptuous as vol
from homeassistant.components.climate import ClimateEntity, ClimateEntityDescription
from homeassistant.components.climate.const import (
ATTR_TARGET_TEMP_HIGH,
ATTR_TARGET_TEMP_LOW,
ClimateEntityFeature,
HVACAction,
HVACMode,
)
from homeassistant.config_entries import ConfigEntry
from homeassistant.const import ATTR_TEMPERATURE
from homeassistant.core import HomeAssistant
from homeassistant.exceptions import HomeAssistantError
from homeassistant.helpers import entity_platform
import homeassistant.helpers.config_validation as cv
from homeassistant.helpers.entity_platform import AddEntitiesCallback
from homeassistant.helpers.update_coordinator import DataUpdateCoordinator
from . import LyricDeviceEntity
from .const import (
DOMAIN,
LYRIC_EXCEPTIONS,
PRESET_HOLD_UNTIL,
PRESET_NO_HOLD,
PRESET_PERMANENT_HOLD,
PRESET_TEMPORARY_HOLD,
PRESET_VACATION_HOLD,
)
_LOGGER = logging.getLogger(__name__)
# Only LCC models support presets
SUPPORT_FLAGS_LCC = (
ClimateEntityFeature.TARGET_TEMPERATURE
| ClimateEntityFeature.PRESET_MODE
| ClimateEntityFeature.TARGET_TEMPERATURE_RANGE
)
SUPPORT_FLAGS_TCC = (
ClimateEntityFeature.TARGET_TEMPERATURE
| ClimateEntityFeature.TARGET_TEMPERATURE_RANGE
)
LYRIC_HVAC_ACTION_OFF = "EquipmentOff"
LYRIC_HVAC_ACTION_HEAT = "Heat"
LYRIC_HVAC_ACTION_COOL = "Cool"
LYRIC_HVAC_MODE_OFF = "Off"
LYRIC_HVAC_MODE_HEAT = "Heat"
LYRIC_HVAC_MODE_COOL = "Cool"
LYRIC_HVAC_MODE_HEAT_COOL = "Auto"
LYRIC_HVAC_MODES = {
HVACMode.OFF: LYRIC_HVAC_MODE_OFF,
HVACMode.HEAT: LYRIC_HVAC_MODE_HEAT,
HVACMode.COOL: LYRIC_HVAC_MODE_COOL,
HVACMode.HEAT_COOL: LYRIC_HVAC_MODE_HEAT_COOL,
}
HVAC_MODES = {
LYRIC_HVAC_MODE_OFF: HVACMode.OFF,
LYRIC_HVAC_MODE_HEAT: HVACMode.HEAT,
LYRIC_HVAC_MODE_COOL: HVACMode.COOL,
LYRIC_HVAC_MODE_HEAT_COOL: HVACMode.HEAT_COOL,
}
HVAC_ACTIONS = {
LYRIC_HVAC_ACTION_OFF: HVACAction.OFF,
LYRIC_HVAC_ACTION_HEAT: HVACAction.HEATING,
LYRIC_HVAC_ACTION_COOL: HVACAction.COOLING,
}
SERVICE_HOLD_TIME = "set_hold_time"
ATTR_TIME_PERIOD = "time_period"
SCHEMA_HOLD_TIME = {
vol.Required(ATTR_TIME_PERIOD, default="01:00:00"): vol.All(
cv.time_period,
cv.positive_timedelta,
lambda td: strftime("%H:%M:%S", localtime(time() + td.total_seconds())),
)
}
async def async_setup_entry(
hass: HomeAssistant, entry: ConfigEntry, async_add_entities: AddEntitiesCallback
) -> None:
"""Set up the Honeywell Lyric climate platform based on a config entry."""
coordinator: DataUpdateCoordinator = hass.data[DOMAIN][entry.entry_id]
entities = []
for location in coordinator.data.locations:
for device in location.devices:
entities.append(
LyricClimate(
coordinator,
ClimateEntityDescription(
key=f"{device.macID}_thermostat",
name=device.name,
),
location,
device,
hass.config.units.temperature_unit,
)
)
async_add_entities(entities, True)
platform = entity_platform.async_get_current_platform()
platform.async_register_entity_service(
SERVICE_HOLD_TIME,
SCHEMA_HOLD_TIME,
"async_set_hold_time",
)
class LyricClimate(LyricDeviceEntity, ClimateEntity):
"""Defines a Honeywell Lyric climate entity."""
coordinator: DataUpdateCoordinator
entity_description: ClimateEntityDescription
def __init__(
self,
coordinator: DataUpdateCoordinator,
description: ClimateEntityDescription,
location: LyricLocation,
device: LyricDevice,
temperature_unit: str,
) -> None:
"""Initialize Honeywell Lyric climate entity."""
self._temperature_unit = temperature_unit
# Setup supported hvac modes
self._attr_hvac_modes = [HVACMode.OFF]
# Add supported lyric thermostat features
if LYRIC_HVAC_MODE_HEAT in device.allowedModes:
self._attr_hvac_modes.append(HVACMode.HEAT)
if LYRIC_HVAC_MODE_COOL in device.allowedModes:
self._attr_hvac_modes.append(HVACMode.COOL)
if (
LYRIC_HVAC_MODE_HEAT in device.allowedModes
and LYRIC_HVAC_MODE_COOL in device.allowedModes
):
self._attr_hvac_modes.append(HVACMode.HEAT_COOL)
super().__init__(
coordinator,
location,
device,
f"{device.macID}_thermostat",
)
self.entity_description = description
@property
def supported_features(self) -> int:
"""Return the list of supported features."""
if self.device.changeableValues.thermostatSetpointStatus:
support_flags = SUPPORT_FLAGS_LCC
else:
support_flags = SUPPORT_FLAGS_TCC
return support_flags
@property
def temperature_unit(self) -> str:
"""Return the unit of measurement."""
return self._temperature_unit
@property
def current_temperature(self) -> float | None:
"""Return the current temperature."""
return self.device.indoorTemperature
@property
def hvac_action(self) -> HVACAction:
"""Return the current hvac action."""
action = HVAC_ACTIONS.get(self.device.operationStatus.mode, None)
if action == HVACAction.OFF and self.hvac_mode != HVACMode.OFF:
action = HVACAction.IDLE
return action
@property
def hvac_mode(self) -> HVACMode:
"""Return the hvac mode."""
return HVAC_MODES[self.device.changeableValues.mode]
@property
def target_temperature(self) -> float | None:
"""Return the temperature we try to reach."""
device = self.device
if (
device.changeableValues.autoChangeoverActive
or HVAC_MODES[device.changeableValues.mode] == HVACMode.OFF
):
return None
if self.hvac_mode == HVACMode.COOL:
return device.changeableValues.coolSetpoint
return device.changeableValues.heatSetpoint
@property
def target_temperature_high(self) -> float | None:
"""Return the highbound target temperature we try to reach."""
device = self.device
if (
not device.changeableValues.autoChangeoverActive
or HVAC_MODES[device.changeableValues.mode] == HVACMode.OFF
):
return None
return device.changeableValues.coolSetpoint
@property
def target_temperature_low(self) -> float | None:
"""Return the lowbound target temperature we try to reach."""
device = self.device
if (
not device.changeableValues.autoChangeoverActive
or HVAC_MODES[device.changeableValues.mode] == HVACMode.OFF
):
return None
return device.changeableValues.heatSetpoint
@property
def preset_mode(self) -> str | None:
"""Return current preset mode."""
return self.device.changeableValues.thermostatSetpointStatus
@property
def preset_modes(self) -> list[str] | None:
"""Return preset modes."""
return [
PRESET_NO_HOLD,
PRESET_HOLD_UNTIL,
PRESET_PERMANENT_HOLD,
PRESET_TEMPORARY_HOLD,
PRESET_VACATION_HOLD,
]
@property
def min_temp(self) -> float:
"""Identify min_temp in Lyric API or defaults if not available."""
device = self.device
if LYRIC_HVAC_MODE_COOL in device.allowedModes:
return device.minCoolSetpoint
return device.minHeatSetpoint
@property
def max_temp(self) -> float:
"""Identify max_temp in Lyric API or defaults if not available."""
device = self.device
if LYRIC_HVAC_MODE_HEAT in device.allowedModes:
return device.maxHeatSetpoint
return device.maxCoolSetpoint
async def async_set_temperature(self, **kwargs) -> None:
"""Set new target temperature."""
if self.hvac_mode == HVACMode.OFF:
return
device = self.device
target_temp_low = kwargs.get(ATTR_TARGET_TEMP_LOW)
target_temp_high = kwargs.get(ATTR_TARGET_TEMP_HIGH)
if device.changeableValues.autoChangeoverActive:
if target_temp_low is None or target_temp_high is None:
raise HomeAssistantError(
"Could not find target_temp_low and/or target_temp_high in arguments"
)
_LOGGER.debug("Set temperature: %s - %s", target_temp_low, target_temp_high)
try:
await self._update_thermostat(
self.location,
device,
coolSetpoint=target_temp_high,
heatSetpoint=target_temp_low,
mode=HVAC_MODES[device.changeableValues.heatCoolMode],
)
except LYRIC_EXCEPTIONS as exception:
_LOGGER.error(exception)
await self.coordinator.async_refresh()
else:
temp = kwargs.get(ATTR_TEMPERATURE)
_LOGGER.debug("Set temperature: %s", temp)
try:
if self.hvac_mode == HVACMode.COOL:
await self._update_thermostat(
self.location, device, coolSetpoint=temp
)
else:
await self._update_thermostat(
self.location, device, heatSetpoint=temp
)
except LYRIC_EXCEPTIONS as exception:
_LOGGER.error(exception)
await self.coordinator.async_refresh()
async def async_set_hvac_mode(self, hvac_mode: HVACMode) -> None:
"""Set hvac mode."""
_LOGGER.debug("HVAC mode: %s", hvac_mode)
try:
if LYRIC_HVAC_MODES[hvac_mode] == LYRIC_HVAC_MODE_HEAT_COOL:
# If the system is off, turn it to Heat first then to Auto, otherwise it turns to
# Auto briefly and then reverts to Off (perhaps related to heatCoolMode). This is the
# behavior that happens with the native app as well, so likely a bug in the api itself
if HVAC_MODES[self.device.changeableValues.mode] == HVACMode.OFF:
_LOGGER.debug(
"HVAC mode passed to lyric: %s",
HVAC_MODES[LYRIC_HVAC_MODE_COOL],
)
await self._update_thermostat(
self.location,
self.device,
mode=HVAC_MODES[LYRIC_HVAC_MODE_HEAT],
autoChangeoverActive=False,
)
# Sleep 3 seconds before proceeding
await asyncio.sleep(3)
_LOGGER.debug(
"HVAC mode passed to lyric: %s",
HVAC_MODES[LYRIC_HVAC_MODE_HEAT],
)
await self._update_thermostat(
self.location,
self.device,
mode=HVAC_MODES[LYRIC_HVAC_MODE_HEAT],
autoChangeoverActive=True,
)
else:
_LOGGER.debug(
"HVAC mode passed to lyric: %s",
HVAC_MODES[self.device.changeableValues.mode],
)
await self._update_thermostat(
self.location, self.device, autoChangeoverActive=True
)
else:
_LOGGER.debug(
"HVAC mode passed to lyric: %s", LYRIC_HVAC_MODES[hvac_mode]
)
await self._update_thermostat(
self.location,
self.device,
mode=LYRIC_HVAC_MODES[hvac_mode],
autoChangeoverActive=False,
)
except LYRIC_EXCEPTIONS as exception:
_LOGGER.error(exception)
await self.coordinator.async_refresh()
async def async_set_preset_mode(self, preset_mode: str) -> None:
"""Set preset (PermanentHold, HoldUntil, NoHold, VacationHold) mode."""
_LOGGER.debug("Set preset mode: %s", preset_mode)
try:
await self._update_thermostat(
self.location, self.device, thermostatSetpointStatus=preset_mode
)
except LYRIC_EXCEPTIONS as exception:
_LOGGER.error(exception)
await self.coordinator.async_refresh()
async def async_set_hold_time(self, time_period: str) -> None:
"""Set the time to hold until."""
_LOGGER.debug("set_hold_time: %s", time_period)
try:
await self._update_thermostat(
self.location,
self.device,
thermostatSetpointStatus=PRESET_HOLD_UNTIL,
nextPeriodTime=time_period,
)
except LYRIC_EXCEPTIONS as exception:
_LOGGER.error(exception)
await self.coordinator.async_refresh()