# Describes the format for available services for KEBA charging staitons
request_data:
name: Request data
description: >
Request new data from the charging station.
authorize:
name: Authorize
description: >
Authorizes a charging process with the predefined RFID tag of the configuration file.
deauthorize:
name: Deauthorize
description: >
Deauthorizes the running charging process with the predefined RFID tag of the configuration file.
set_energy:
name: Set energy
description: Sets the energy target after which the charging process stops.
fields:
energy:
name: Energy
description: >
The energy target to stop charging. Setting 0 disables the limit.
selector:
number:
min: 0
max: 100
step: 0.1
unit_of_measurement: "kWh"
set_current:
name: Set current
description: Sets the maximum current for charging processes.
fields:
current:
name: Current
description: >
The maximum current used for the charging process.
The value is depending on the DIP-switch settings and the used cable of the
charging station.
default: 6
selector:
number:
min: 6
max: 63
step: 0.1
unit_of_measurement: "A"
enable:
name: Enable
description: >
Starts a charging process if charging station is authorized.
disable:
name: Disable
description: >
Stops the charging process if charging station is authorized.
set_failsafe:
name: Set failsafe
description: >
Set the failsafe mode of the charging station. If all parameters are 0, the failsafe mode will be disabled.
fields:
failsafe_timeout:
name: Failsafe timeout
description: >
Timeout after which the failsafe mode is triggered, if set_current was not executed during this time.
default: 30
selector:
number:
min: 1
max: 3600
unit_of_measurement: seconds
failsafe_fallback:
name: Failsafe fallback
description: >
Fallback current to be set after timeout.
default: 6
selector:
number:
min: 6
max: 63
step: 0.1
unit_of_measurement: "A"
failsafe_persist:
name: Failsafe persist
description: >
If failsafe_persist is 0, the failsafe option is only until charging station reboot. If failsafe_persist is 1, the failsafe option will survive a reboot.
default: 0
selector:
number:
min: 0
max: 1