Commit Graph

253 Commits

Author SHA1 Message Date
Franck Nijhof ed79265843
Enable Ruff PT006 (#88165)
* Enable Ruff PT006

* Adjust existing cases

* Fix tests

* Remove unneeded parentheses
2023-02-15 14:09:50 +01:00
epenet 9f688a564f
Add type hints to integration tests (part 4) (#87848) 2023-02-11 08:26:13 +01:00
Erik Montnemery cc564026fa
Move EntityCategory to homeassistant.const (#87792)
* Move EntityCategory to homeassistant.const

* Fix more imports
2023-02-09 20:15:37 +01:00
epenet 3052de3e8e
Add type hints to integration tests (d-e) (#87699) 2023-02-08 13:01:44 +01:00
Franck Nijhof 5e81d28116
Update black to 23.1.0 (#87188) 2023-02-02 18:35:24 +01:00
epenet 67f8d82818
Remove invalid state class in deconz (#85615) 2023-01-10 17:28:35 +01:00
Franck Nijhof 5c794234e7
Fix incorrect voc device class usage in Deconz sensors (#84371) 2022-12-21 22:44:13 +01:00
Jelte Zeilstra 3fc667f55d
Fix error when describing deCONZ events of removed devices (#84194)
* Fix error when describing deCONZ events of removed devices

* Apply suggestions from code review

Co-authored-by: Robert Svensson <Kane610@users.noreply.github.com>

Co-authored-by: Robert Svensson <Kane610@users.noreply.github.com>
2022-12-20 10:06:01 +01:00
Erik Montnemery 774ebc760c
Ignore certain device trigger validation errors (#83972) 2022-12-14 16:41:11 +01:00
Robert Svensson 3853182ccf
Add deconz_relative_rotary event for Hue Tap Dial (#82727) 2022-11-27 15:01:58 -05:00
Robert Svensson e1a0f8314e
Fix deCONZ Air Quality PPB device class and unit of measurement (#82726)
Fix Air Quality PPB device class and unit of measurement
2022-11-26 10:56:09 +01:00
Aarni Koskela 6021cedb09
deconz: Use partition instead of split where possible (#81804)
* deconz: Use partition instead of split where possible

With a smattering of code deduplication

Split out of #81493

* Update homeassistant/components/deconz/util.py

Co-authored-by: Robert Svensson <Kane610@users.noreply.github.com>

Co-authored-by: Robert Svensson <Kane610@users.noreply.github.com>
2022-11-08 20:54:01 +01:00
Robert Svensson d75834cd1e
Add presence duration number (#79498) 2022-10-23 22:30:03 +02:00
Martin Hjelmare 62c4cd3c26
Add name and slug to supervisor discovery info (#80094) 2022-10-11 16:56:45 +02:00
Robert Svensson 2ce837f588
Resolve late comments to deCONZ sensor (#79380)
Resolve late comments to deCONZ sensor #79137
2022-09-30 21:49:59 +02:00
epenet 0d696b84b2
Cleanup root component imports in tests (#78893) 2022-09-21 06:57:41 -10:00
Michael Jäger 7a6897c757
Add deconz current hvac operation to thermostate based on "state" (#59989)
* deconz - add current hvac operation to thermostate based on "state"

* deconz - extend current hvac operation to thermostate based on "state" and "mode"

* Add tests for current hvac action

* Add boost mode as special case

* format using Black

* sort imports

* Add test for device with mode none and state none

* Update homeassistant/components/deconz/climate.py

Co-authored-by: Robert Svensson <Kane610@users.noreply.github.com>

* Fix test_climate.py test_no_mode_no_state

* Add test for boost mode

Co-authored-by: Robert Svensson <Kane610@users.noreply.github.com>
2022-09-21 08:20:44 +02:00
Robert Svensson 61ff52c93a
Normalize deCONZ sensor unique IDs (#76357)
* Normalize deCONZ sensor unique IDs

* Handle battery sensors properly

* Fix daylight sensor unique ID
2022-08-31 08:12:25 +02:00
Robert Svensson ff3d3088ee
Add Aqara FP1 support to deCONZ integration (#77568) 2022-08-30 23:33:05 -04:00
Robert Svensson 2161b6f049
Fix level controllable output controls in deCONZ (#77223)
Fix level controllable output controls
2022-08-24 22:00:54 -04:00
Robert Svensson c2f026d0a7
Minor deCONZ clean up (#76323)
* Rename secondary_temperature with internal_temperature

* Prefix binary and sensor descriptions matching on all sensor devices with COMMON_

* Always create entities in the same order

Its been reported previously that if the integration is removed and setup again that entity IDs can change if not sorted in the numerical order

* Rename alarmsystems to alarm_systems

* Use websocket enums

* Don't use legacy pydeconz constants

* Bump pydeconz to v103

* unsub -> unsubscribe
2022-08-06 01:34:27 +02:00
Robert Svensson 3b3766fbe0
Bump deconz dependency to fix #74523 (#74710) 2022-07-08 12:54:09 +02:00
Robert Svensson b071affcb4
Use pydeconz interface controls for cover platform (#74535) 2022-07-07 00:31:47 +02:00
Robert Svensson 05416f56aa
Use FlowResultType in deCONZ config flow tests (#74495) 2022-07-06 09:45:30 +02:00
Robert Svensson abf67c3153
Normalize deCONZ binary sensor unique IDs (#73657) 2022-06-28 13:45:25 -07:00
Robert Svensson aef69f87f4
More enums in deCONZ Alarm Control Panel (#73800) 2022-06-22 23:02:34 +02:00
Robert Svensson e60b247b51
Simplify setup of deCONZ platforms (#72453) 2022-05-24 20:48:09 -07:00
Franck Nijhof c3d19f3827
Clean up accessing device_registry helpers via hass (#72031) 2022-05-17 12:22:15 -07:00
J. Nick Koston 24a0007785
Add additional context data to logbook events (#71721) 2022-05-12 17:21:14 -07:00
J. Nick Koston 24d7a464e1
Refactor logbook to reduce overhead and complexity (#71509) 2022-05-08 21:47:26 -07:00
Jelte Zeilstra d52137cc1a
Add state class measurement to deCONZ LightLevel sensors (#71516) 2022-05-08 15:54:43 +02:00
Robert Svensson 37b59dfcc0
Make sure sensor state value is not None prior to trying to used the scaled value (#71189) 2022-05-02 10:51:19 +03:00
Robert Svensson a0fe5b0247
Make deCONZ SSDP discovery more strict by matching on manufacturerURL (#71124) 2022-04-30 19:33:47 +02:00
Robert Svensson 7f094a928b
Fix linking issue when deCONZ gateway is not unlocked (#71082) 2022-04-29 15:34:33 -07:00
Robert Svensson e1f4b17971
Pydeconz raise ResponseError when deCONZ Rest API Plugin is not yet ready (#71078) 2022-04-29 23:55:55 +03:00
epenet 7d2363ad22
Use light enums in tests (#70801) 2022-04-26 16:32:00 +02:00
Robert Svensson f7d9797c62
Streamline setup of deCONZ scene platform (#70700) 2022-04-26 11:42:56 +02:00
epenet 9dcbc8469e
Use climate enums in deconz (#70630)
* Use climate enums in deconz

* Adjust tests

* Adjust type hint

* Update climate.py

* Update climate.py

* Update climate.py

* Don't edit files in Github!
2022-04-25 16:18:44 +02:00
Robert Svensson 8eae572c93
Mark type "On/Off Switch" as a deCONZ switch entity (#70598)
Convert entity types of light platform to switch platform
2022-04-25 08:25:38 +02:00
Robert Svensson b15387ffb9
Remove migration of entities from deCONZ switch to siren platform (#70600) 2022-04-24 23:32:13 +02:00
Robert Svensson 009111151d
Move deCONZ alarm system imports to reflect the changes in pydeconz (#70453) 2022-04-24 10:17:46 +02:00
Robert Svensson 301dcaae63
Move deCONZ sensor imports to reflect changes in pydeconz (#70471) 2022-04-23 22:59:51 +03:00
Erik Montnemery 5e50a8abd5
Mark device triggers from hidden or auxiliary entities as secondary (#70335)
* Mark device triggers from hidden or auxiliary entities as secondary

* Update tests
2022-04-21 08:01:32 +02:00
Robert Svensson f0b1d35562
Address late review of deconz climate (#70148)
* Fix late comment

* Avoid unnecessary properties

* Add clip sensor test to increase coverage of climate

* Fix review_comment
2022-04-16 21:14:54 +02:00
Robert Svensson 87551b7880
Improve typing of deCONZ climate platform (#69882)
* Improve typing of deCONZ climate platform

homeassistant/components/deconz/climate.py:153: error: Dict entry 0 has incompatible type "str": "bool"; expected "str": "str"  [dict-item]
homeassistant/components/deconz/climate.py:154: error: Dict entry 1 has incompatible type "str": "bool"; expected "str": "str"  [dict-item]
homeassistant/components/deconz/climate.py:176: error: Argument 1 to "get" of "Mapping" has incompatible type "Optional[Literal['off', 'low', 'medium', 'high', 'on', 'auto', 'smart']]"; expected "str"  [arg-type]
homeassistant/components/deconz/climate.py:200: error: Argument 1 to "get" of "Mapping" has incompatible type "Optional[Literal['off', 'auto', 'cool', 'heat', 'emergency heating', 'precooling', 'fan only', 'dry', 'sleep']]"; expected "str"  [arg-type]
homeassistant/components/deconz/climate.py:218: error: Argument 1 to "set_config" of "Thermostat" has incompatible type "**Dict[str, str]"; expected "Optional[int]"  [arg-type]
homeassistant/components/deconz/climate.py:218: error: Argument 1 to "set_config" of "Thermostat" has incompatible type "**Dict[str, str]"; expected "Optional[bool]"  [arg-type]
homeassistant/components/deconz/climate.py:218: error: Argument 1 to "set_config" of "Thermostat" has incompatible type "**Dict[str, str]"; expected "Optional[List[str]]"  [arg-type]
homeassistant/components/deconz/climate.py:225: error: Argument 1 to "get" of "Mapping" has incompatible type "Optional[Literal['holiday', 'auto', 'manual', 'comfort', 'eco', 'boost', 'complex']]"; expected "str"  [arg-type]
homeassistant/components/deconz/climate.py:244: error: Unused "type: ignore" comment
homeassistant/components/deconz/climate.py:250: error: Unused "type: ignore" comment
homeassistant/components/deconz/climate.py:253: error: Unused "type: ignore" comment

* Simplify populating supported_hvac_modes
Fix tests
2022-04-14 23:19:42 +03:00
Robert Svensson d6d7f3cb3c
Bump pydeconz to v88 (#69369) 2022-04-05 13:44:04 -07:00
Robert Svensson 4bb52297a6
Replace hass helper calls in deCONZ device trigger tests (#68197) 2022-03-15 18:51:12 +01:00
Robert Svensson 362191a0e6
Add typing of deCONZ device_trigger (#67496) 2022-03-14 17:37:48 +01:00
J. Nick Koston 723dcbafca
Complete fan speed transition from #59781 (#67743) 2022-03-09 10:38:12 +01:00
Robert Svensson dd88a05cb4
Make type checking pass for deCONZ init, gateway and services (#66054)
* Type and enable type checking for init, config_flow, diagnostics, gateway and services

* Fix import

* Fix review comment
2022-02-23 13:10:35 +01:00