// Configuration topic no1: %homeassistant%/sensor/<name node>/config
|
|
// Configuration Payload no1: {"unique_id": "otgw", "name": "flame", "state_topic": "%OTGW%/flame"}
|
|
%homeassistant%/binary_sensor/OTGW/fault/config , {"unique_id": "otgw","name": "Fault", "state_topic": "%OTGW%/fault"}
|
|
%homeassistant%/binary_sensor/OTGW/centralheating/config , {"name": "Central Heating", "state_topic": "%OTGW%/centralheating"}
|
|
%homeassistant%/binary_sensor/OTGW/domestichotwater/config , {"name": "Domestic Hot Water", "state_topic": "%OTGW%/domestichotwater"}
|
|
%homeassistant%/binary_sensor/OTGW/flame/config , {"name": "Flame", "state_topic": "%OTGW%/flame"}
|
|
%homeassistant%/binary_sensor/OTGW/cooling/config , {"name": "Cooling", "state_topic": "%OTGW%/cooling"}
|
|
%homeassistant%/binary_sensor/OTGW/centralheating2/config , {"name": "Central Heating 2", "state_topic": "%OTGW%/centralheating2"}
|
|
%homeassistant%/binary_sensor/OTGW/diagnostic_indicator/config , {"name": "Diagonostic Indicator", "state_topic": "%OTGW%/diagnostic_indicator"}
|
|
|
|
%homeassistant%/binary_sensor/OTGW/ch_enable/config , {"name": "Central Heating enable", "state_topic": "%OTGW%/ch_enable"}
|
|
%homeassistant%/binary_sensor/OTGW/dhw_enable/config , {"name": "Domestic Hot Water enable", "state_topic": "%OTGW%/dhw_enable"}
|
|
%homeassistant%/binary_sensor/OTGW/cooling_enable/config , {"name": "Cooling enable", "state_topic": "%OTGW%/cooling_enable"}
|
|
%homeassistant%/binary_sensor/OTGW/otc_active/config , {"name": "OTC enable", "state_topic": "%OTGW%/otc_active"}
|
|
%homeassistant%/binary_sensor/OTGW/ch2_enable/config , {"name": "central heating 2 enable", "state_topic": "%OTGW%/ch2_enable"}
|
|
|
|
%homeassistant%/binary_sensor/OTGW/service_request/config , {"name": "Service request", "state_topic": "%OTGW%/service_request"}
|
|
%homeassistant%/binary_sensor/OTGW/lockout_reset/config , {"name": "Lockout-reset", "state_topic": "%OTGW%/lockout_reset"}
|
|
%homeassistant%/binary_sensor/OTGW/low_water_pressure/config , {"name": "Low water press", "state_topic": "%OTGW%/low_water_pressure"}
|
|
%homeassistant%/binary_sensor/OTGW/gas_flame_fault/config , {"name": "Gas/flame fault", "state_topic": "%OTGW%/gas_flame_fault"}
|
|
%homeassistant%/binary_sensor/OTGW/air_pressure_fault/config , {"name": "Air press fault", "state_topic": "%OTGW%/air_pressure_fault"}
|
|
%homeassistant%/binary_sensor/OTGW/water_over-temperature/config , {"name": "Water over-temp", "state_topic": "%OTGW%/water_over-temperature"}
|
|
|
|
%homeassistant%/binary_sensor/OTGW/dhw_present/config , {"name": "DHW present", "state_topic": "%OTGW%/dhw_present"}
|
|
%homeassistant%/binary_sensor/OTGW/control_type/config , {"name": "Control type", "state_topic": "%OTGW%/control_type"}
|
|
%homeassistant%/binary_sensor/OTGW/cooling_config/config , {"name": " Cooling configs", "state_topic": "%OTGW%/cooling_config"}
|
|
%homeassistant%/binary_sensor/OTGW/dhw_config/config , {"name": "DHW config", "state_topic": "%OTGW%/dhw_config"}
|
|
%homeassistant%/binary_sensor/OTGW/master_low_off_pomp_control_function/config , {"name": "Master low-off&pump control function", "state_topic": "%OTGW%/master_low_off_pomp_control_function"}
|
|
%homeassistant%/binary_sensor/OTGW/ch2_present/config , {"name": "CH2 present", "state_topic": "%OTGW%/ch2_present"}
|
|
|
|
// Configuration topic no2: %homeassistant%/sensor/<name node>/config
|
|
// Configuration payload no1: {"device_class": "temperature", "name": "Temperature", "state_topic": "%OTGW%/<sensor name>>", "unit_of_measurement": "°C", "value_template": "{{ value_json.temperature}}" }
|
|
%homeassistant%/sensor/OTGW/TSet/config , {"device_class": "temperature", "name": "Control setpoint", "state_topic": "%OTGW%/TSet", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/TsetCH2/config , {"device_class": "temperature", "name": "Control setpoint for 2e circuit", "state_topic": "%OTGW%/TsetCH2", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/TrOverride/config , {"device_class": "temperature", "name": "Remote override room setpoint", "state_topic": "%OTGW%/TrOverride", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/TrSet/config , {"device_class": "temperature", "name": "Room setpoint", "state_topic": "%OTGW%/TrSet", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/Troom/config , {"device_class": "temperature", "name": "Room Temperature", "state_topic": "%OTGW%/Tr", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/Tboiler/config , {"device_class": "temperature", "name": "Boiler flow water temperature", "state_topic": "%OTGW%/Tboiler", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/Tdhw/config , {"device_class": "temperature", "name": "DHW temperature", "state_topic": "%OTGW%/Tdhw", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/Toutside/config , {"device_class": "temperature", "name": "Outside Temperature", "state_topic": "%OTGW%/Toutside", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/Tret/config , {"device_class": "temperature", "name": "Return water temperature", "state_topic": "%OTGW%/Tret", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/Tstorage/config , {"device_class": "temperature", "name": "Solar storage temperature", "state_topic": "%OTGW%/Tstorage", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/Tcollector/config , {"device_class": "temperature", "name": "Solar collector temperature", "state_topic": "%OTGW%/Tcollector", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/TflowCH2/config , {"device_class": "temperature", "name": "Flow water temperature CH2 cir.", "state_topic": "%OTGW%/TflowCH2", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/Tdhw2/config , {"device_class": "temperature", "name": "Domestic hot water temperature 2", "state_topic": "%OTGW%/Tdhw2", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/Texhaust/config , {"device_class": "temperature", "name": "Boiler exhaust temperature", "state_topic": "%OTGW%/Texhaust", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/TdhwSet/config , {"device_class": "temperature", "name": "DHW setpoint", "state_topic": "%OTGW%/TdhwSet", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/MaxTSet/config , {"device_class": "temperature", "name": "Max CH water setpoint", "state_topic": "%OTGW%/MaxTSet", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/CoolingControl/config , {"name": "Cooling control signal", "state_topic": "%OTGW%/CoolingControl", "unit_of_measurement": "%", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/MaxRelModLevelSetting/config , {"name": "Max Rel Modulation level setting", "state_topic": "%OTGW%/MaxRelModLevelSetting", "unit_of_measurement": "%", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/RelModLevel/config , {"name": "Relative Modulation Level", "state_topic": "%OTGW%/RelModLevel", "unit_of_measurement": "%", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/CHPressure/config , {"name": "Water pressure in CH circuit", "state_topic": "%OTGW%/CHPressure", "unit_of_measurement": "bar", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/DHWFlowRate/config , {"name": "Water flow rate in DHW circuit", "state_topic": "%OTGW%/DHWFlowRate", "unit_of_measurement": "l/min", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/Hcratio/config , {"device_class": "temperature", "name": "OTC heat curve ratio", "state_topic": "%OTGW%/DHWFlowRate", "unit_of_measurement": "°C", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/OpenThermVersionMaster/config , {"name": "Master OT protocol version", "state_topic": "%OTGW%/OpenThermVersionMaster", "unit_of_measurement": "l/min", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/OpenThermVersionSlave/config , {"name": "Slave OT protocol version", "state_topic": "%OTGW%/OpenThermVersionSlave", "unit_of_measurement": "l/min", "value_template": "{{ value }}" }
|
|
//Statistics
|
|
%homeassistant%/sensor/OTGW/BurnerStarts/config , {"name": "Nr of starts burner", "state_topic": "%OTGW%/BurnerStarts", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/CHPumpStarts/config , {"name": "Nr of starts CH pump", "state_topic": "%OTGW%/CHPumpStarts", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/DHWPumpValveStarts/config , {"name": "Nr of starts DHW pump or valve", "state_topic": "%OTGW%/DHWPumpValveStarts", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/DHWBurnerStarts/config , {"name": "Nr of starts burner during DHW", "state_topic": "%OTGW%/DHWBurnerStarts", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/BurnerOperationHours/config , {"name": "Nr of hours burner operation", "state_topic": "%OTGW%/BurnerOperationHours", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/CHPumpOperationHours/config , {"name": "Nr of hours CH pump running", "state_topic": "%OTGW%/CHPumpOperationHours", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/DHWPumpValveOperationHours/config , {"name": "Nr of hours DHW valve open", "state_topic": "%OTGW%/DHWPumpValveOperationHours", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/DHWBurnerOperationHours/config , {"name": "Nr of hours burner operation DHW", "state_topic": "%OTGW%/DHWBurnerOperationHours", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
|
|
%homeassistant%/sensor/OTGW/status_master/config , {"name": "Status Master", "state_topic": "%OTGW%/status_master", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/status_slave/config , {"name": "Status Slave", "state_topic": "%OTGW%/status_slave", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
|
|
%homeassistant%/sensor/OTGW/ASF_flags/config , {"name": "Application Specific Fault", "state_topic": "%OTGW%/ASF_flags", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/ASF_oemfaultcode/config , {"name": "ASF OEM fault code", "state_topic": "%OTGW%/ASF_oemfaultcode", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
|
|
%homeassistant%/sensor/OTGW/master_configuration/config , {"name": "Status Master Configuration", "state_topic": "%OTGW%/master_configuration", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/master_memberid_code/config , {"name": "Status Master Memberid Code", "state_topic": "%OTGW%/master_memberid_code", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/slave_configuration/config , {"name": "Status Slave Configuration", "state_topic": "%OTGW%/slave_configuration", "unit_of_measurement": "", "value_template": "{{ value }}" }
|
|
%homeassistant%/sensor/OTGW/slave_memberid_code/config , {"name": "Status Slave Memberid Code", "state_topic": "%OTGW%/slave_memberid_code", "unit_of_measurement": "", "value_template": "{{ value }}" }
|